Financial Payback and Annual Savings for the Infinity Turbine IT250, IT1000, and IT10MW Systems

Financial Payback and Annual Savings Analysis

A detailed look at operating costs, annual savings, and payback periods for Infinity Turbine systems ranging from 250 kW to 10 MW, showing how high efficiency supercritical CO2 turbines outperform purchased grid electricity.


Financial Payback and Annual Savings Analysis

Below are the assumptions used for the comparison:

Key Assumptions

• Heat rate: 10,000 BTU per kWh

• Natural gas price: $10 dollars per MMBTU (average US commercial retail rate)

• Electricity value: $0.20 dollars per kWh

• Continuous operation: 24 hours a day, 365 days a year

• Hours per year: 8760

Gas Fuel Cost per kWh

10,000 BTU per kWh equals 0.01 MMBTU.

Natural gas at $10 dollars per MMBTU results in a fuel cost of $0.10 dollars per kWh.

Value of Produced Electricity

Electricity worth $0.20 dollars per kWh.

Fuel cost $0.10 dollars per kWh.

Net savings per kWh produced: $0.10 dollars.

Annual Operating Savings

Savings = Output in kW multiplied by hours per year multiplied by savings per kWh.

IT250 System

• Output: 250 kW

• Annual kWh: 250 x 8760 = 2,190,000 kWh

• Annual savings: 2,190,000 x $0.10 = $219,000

IT1000 System

• Output: 1,000 kW

• Annual kWh: 1,000 x 8760 = 8,760,000 kWh

• Annual savings: 8,760,000 x $0.10 = $876,000

IT10MW System

• Output: 10,000 kW

• Annual kWh: 10,000 kW × 8760 h = 87,600,000 kWh

• Annual savings: 87,600,000 kWh × $0.10 = $8,760,000

Payback Period Calculations

Payback equals system cost divided by annual savings.

IT250

• Cost: $999,000 dollars

• Annual savings: $219,000 dollars

• Payback: $999,000 divided by $219,000

• Payback: 4.56 years

IT1000

• Cost: $3,000,000 dollars

• Annual savings: $876,000 dollars

• Payback: $3,000,000 divided by $876,000

• Payback: 3.42 years

IT10MW (10,000 kW system, $30,000,000 USD)

• Annual electricity produced

10,000 kW × 8760 h = 87,600,000 kWh per year

• Annual savings

87,600,000 kWh × $0.10 = $8,760,000 USD per year

•Simple payback

$30,000,000 ÷ $8,760,000 = 3.42 years

Summary

Using a heat rate of 10,000 BTU per kWh and a standard commercial natural gas price of $1.00 per therm, the cost to generate power is approximately $0.10 per kWh. When compared with a grid electricity rate of $0.20 per kWh, users save $0.10 for each kilowatt hour produced on site. For continuous year round operation, the IT250 yields savings of $219,000 dollars per year with a payback of 4.56 years. The IT1000 and IT10MW systems achieve payback in about 3.4 years with annual savings of $876,000 dollars and $8.76 million dollars respectively. These results show that natural gas turbine generation provides substantial economic benefits for data centers, industrial users, and any facility operating around the clock.


INFINITY TURBINE LLC We specialize in designs, plans, licensing, consulting, design services, and surplus spare parts. We no longer manufacture turbines or CO2 systems. More Info...

Please email for first contact with request for more information

Email: greg@infinityturbine.com

Infinity Turbine CO2 Turbine Development and Testing Cart Supercritical CO2 Turbine Development Cart using high pressure filter canisters for rapid prototyping and commercialization for 1-25 kWh Power Generation... More Info

ORC and sCO2 Performance Charts: R134a, R245fa, CO2 – 2026 Edition Updated 2026 edition of Infinity Turbine’s ORC and supercritical CO2 performance curves: R134a, R245fa and CO2 charts, CO2 heat-rate tables from 100 to 700 °C, sCO2 turbine types, and data-center applications. 62-page PDF... More Info

Supercritical CO2 Turbine Generator Plans (Transcritical) Rankine Cycle Lab format for development ... More Info

Matra Concentrated Solar Project Using Infinity Turbine Generator for Power Production Solar thermal power production using a reflective dish concentrator... More Info

Cluster Mesh Supercritical CO2 Power System for Data Centers and AI Pairing Cluster Mesh Supercritical CO2 Power System with Small Modular Reactors enables hyperscalers to convert high-grade nuclear heat into ultra-efficient, dispatchable power with a compact, modular footprint tailored for AI-scale demand. More Info

ORC and Products Index Infinity Turbine ORC Index... More Info

A Generator Without Magnets Switched Reluctance is the simplest rotating electrical machine there is: a rotor of stacked steel laminations with salient teeth, and a stator carrying concentrated coils. The rotor has no magnets, no windings, no bars and no slip rings... More Info

CONTACT Email: greg@infinityturbine.com (Standard Web Page) | PDF