Cluster Mesh sCO₂ Turbine with an Air-Cooled Switched Reluctance Generator

Keep the turbine in the CO₂, keep the generator in the air, and keep the magnets out entirely.

Infinity Turbine's Cluster Mesh supercritical CO₂ turbine can drive a generator that lives outside the CO₂ loop entirely: a magnet-free switched reluctance generator (SRG), cooled by ordinary air and running at around 60,000 rpm.

The pairing plays to each machine's strengths. The turbine stays compact, sealed and efficient in dense supercritical CO₂. The generator stays in air, where windage is low, heat is easy to reject, and technicians can reach it. And because a switched reluctance machine has no permanent magnets, the generator needs no rare-earth materials at all.

Why supercritical CO₂, and why a cluster

Supercritical CO₂ packs a lot of power into a very small turbine. Above its critical point (31 °C, 73.8 bar), CO₂ is dense like a liquid but flows like a gas, so the turbomachinery for a given output is a fraction of the size of a steam turbine.

Small turbines spin fast. Instead of one large machine, Cluster Mesh uses many compact turbine modules working in parallel. That approach brings three practical benefits:

The catch is that each module runs at tens of thousands of rpm, and the generator attached to it must keep up.

Why the generator moves outside the CO₂

A generator immersed in supercritical CO₂ pays a heavy price in windage. Drag on a spinning rotor scales roughly with fluid density and with the cube of speed, and supercritical CO₂ is around a hundred times denser than air or more. At high rpm, a submerged rotor can lose a meaningful share of the turbine's output just stirring the fluid around it.

Placing the generator outside the pressure boundary, in ambient air, removes that penalty and brings further advantages:

Only the turbine sits in the CO₂; the generator runs in open air Sealed sCO₂ loop Ambient air sCO₂ turbine Cluster Mesh module Shaft seal or magnetic coupling SR generator air-cooled magnet-free SiC converter excitation and angle control DC bus to loads and storage Heat in
Figure 1. Drivetrain layout. Shaft power crosses the pressure boundary once, at the seal or coupling; everything electrical sits in open air.

The trade-off is that power must cross the pressure boundary mechanically. The two usual options are a shaft through a dry gas seal, or a magnetic coupling acting through a sealed non-metallic containment wall. The best choice depends on module power, allowable leakage and coupling losses at speed. A dry gas seal keeps the whole drivetrain magnet-free; a magnetic coupling brings magnets back, though not necessarily rare-earth ones.

Why a switched reluctance generator

A switched reluctance machine is the simplest rotating electrical machine there is: a rotor of stacked steel laminations with salient teeth, and a stator carrying concentrated coils. The rotor has no magnets, no windings, no bars and no slip rings.

That simplicity is exactly what a high-speed, air-cooled generator needs:

Switched reluctance starter-generators were developed for aircraft engines for many of these same reasons: high speed, high temperature and a need to keep running after a fault.

How it makes power

A switched reluctance generator produces DC through its converter, stroke by stroke. Each phase works in a two-step cycle as the rotor teeth pass the stator poles:

  1. Excite. As a rotor tooth reaches alignment with a stator pole, the converter connects that phase to the DC bus and builds up magnetic flux.
  2. Generate. The switches open as the tooth pulls away. Because the magnetic path is opening up, the phase current is pushed back through diodes into the DC bus. More energy returns than was borrowed, and the difference is the turbine's work converted to electricity.

The controller sets output by adjusting just two numbers: the rotor angles at which each phase is switched on and off. Closed-loop control of those angles holds the DC bus voltage steady as turbine power varies.

The output is native DC, which suits modern facilities well. It can feed a DC distribution bus or battery storage directly, or pass through an inverter for AC loads and grid export. The machine needs a small DC source, such as a battery or charged capacitor, to start; once running, it sustains its own excitation.

Designing for 60,000 rpm

At 60,000 rpm, a switched reluctance generator is well within proven territory; commercial switched reluctance motors have run near 100,000 rpm. The design choices that make it work at this speed are well understood.

Figure 2. Rotor size sets the stress. Peak hoop stress in a rotating steel disk at 60,000 rpm, from the standard rotating-disk equations (density 7,650 kg/m³, Poisson's ratio 0.3). A shaft bore roughly doubles the peak. Salient teeth add local stress at their roots, so real designs need margin below these curves. Yield strength varies widely by lamination grade.
Figure 3. Pole count sets the switching rate. Excitation strokes per second in each phase equal the rotor revolutions per second times the number of rotor teeth. Fewer rotor teeth keep core loss and switching demands down at high speed.
Design issueWhat happens at 60,000 rpmDesign response
Rotor stressA 100 mm rotor sees a tip speed of about 314 m/sKeep rotor diameter around 60–80 mm, or use high-strength cobalt-iron laminations; generous fillets at the tooth roots
Core lossA 6/4 machine switches each phase about 4,000 times per secondLow pole counts and thin laminations (0.1–0.2 mm)
Flux build-upEach excitation window lasts only tens of microsecondsAdequate DC bus voltage and few turns per coil
SwitchingFast, precise angle timingSingle-pulse control with silicon carbide power devices and a fast position sensor or sensorless estimator
Radial forcesSmall air gap plus any eccentricity produces magnetic side pullAccount for it in bearing selection and rotordynamics
WindageSalient rotor teeth churn the surrounding airFill or shroud the gaps between teeth for a smooth rotor surface

Operating in air rather than CO₂ makes the windage line far easier to handle. In air, a lightly shrouded rotor has modest drag. Submerged in supercritical CO₂, the same rotor would be a serious loss.

The trade-offs

No generator choice is free, and the switched reluctance route has known costs:

For a modular, high-speed generator that must be robust, cool easily, and avoid rare earths, these trade-offs are often worth making.

Application: turning data center heat into power

Data centers reject enormous amounts of heat, and most of it is thrown away. A Cluster Mesh system can recover part of that energy, or heat from on-site generation, and convert it back into electricity close to the load.

The switched reluctance generator fits this setting well:

Learn more

Keeping the generator out of the CO₂ and the magnets out of the generator gives a drivetrain that is simple, cool-running, serviceable and free of rare-earth supply risk. That makes it a strong candidate for modular sCO₂ power at data center scale.

To discuss Cluster Mesh for your site or project, contact Infinity Turbine at infinityturbine.com or greg@infinityturbine.com.