01Summary
What the system is, what it can produce, and the main design decisions.
Concept. CO₂ is pumped as a liquid to about 110 bar (1,595 psia), above its critical pressure of 73.8 bar. It is heated by 100 °C water to 95 °C (203 °F) and admitted to double-acting cylinders. Each CO₂ piston is joined by a rod to a hydraulic plunger. The plunger draws oil from the reservoir and pushes it through check valves into an accumulator at 207 bar (3,000 psi). The exhaust CO₂ (about 58 bar, 48 °C) gives up heat in a recuperator. It is then condensed at 20 °C / 57 bar (68 °F / 831 psia) with 15 °C cooling water and pumped back to high pressure.
Why CO₂. With a 15 °C sink, CO₂ condenses below its 31 °C critical temperature. That allows a real liquid pump and a transcritical cycle. The working pressures are high, so the gas is dense and a short-stroke piston expander stays compact. The pressures also fall naturally in the range of industrial hydraulic components.
Power. The 500,000 BTU/h burner delivers about 117 kW (400,000 BTU/h) to the hot-water loop at 80 % boiler efficiency. That heat gives 11.2–12.2 kW (15–16 hp) of gross hydraulic power. After the CO₂ feed pump is driven, 4.3–5.3 kW (5.7–7.2 hp) of net hydraulic power is left over.
Headline results (design point, 110 bar)
| Option A full admission | Option B cutoff + expansion | |
|---|---|---|
| Heat to CO₂ | 117.2 kW 400,000 BTU/h | 117.2 kW 400,000 BTU/h |
| CO₂ mass flow | 0.596 kg/s 4,730 lb/h | 0.591 kg/s 4,690 lb/h |
| Expander indicated work | 12.2 kW · 16.4 hp | 13.3 kW · 17.8 hp |
| Gross hydraulic out | 11.2 kW · 15.1 hp | 12.2 kW · 16.4 hp |
| CO₂ feed pump (shaft) | 5.9 kW · 7.9 hp | 5.9 kW · 7.9 hp |
| Net hydraulic, self-powered* | 4.3 kW · 5.7 hp | 5.3 kW · 7.2 hp |
| Oil flow at 207 bar / 3,000 psi | 32.6 L/min · 8.6 gpm | 35.5 L/min · 9.4 gpm |
| Cycle efficiency | 4.5 % | 5.4 % |
| Fuel → net hydraulic | 2.9 % | 3.6 % |
*CO₂ feed pump driven by a hydraulic motor (85 % efficient) from the system's own output. If the pump is driven by an electric motor instead, the full gross hydraulic power is available and the pump draws about 6.5 kW of electricity.
02Piping & instrumentation diagram
Three circuits: pressurised hot water, transcritical CO₂, and 207 bar hydraulic oil. Stream numbers refer to the state table in Section 03.
Equipment list
| Tag | Service | Duty / size | Design conditions |
|---|---|---|---|
| B-101 | Wood-fired hot-water boiler | 500,000 BTU/h (146.5 kW) firing; ~400,000 BTU/h (117 kW) to the loop | 110 °C / 230 °F; 6 bar(g) / 87 psig |
| P-101 | Hot-water circulation pump | 2.6 m³/h (11.4 gpm), ~1.5 bar (22 psi) head; ~0.25 kW | 110 °C; 6 bar(g) |
| TV-101 | 3-way return-temperature valve | Keeps boiler return ≥ 60 °C (140 °F) against creosote and condensation | — |
| ET-101 | Expansion tank | Loop pressurised to ~3 bar(g) (44 psig) so 100 °C water stays liquid | 6 bar(g) |
| HX-101 | CO₂ gas heater (water → CO₂), counterflow | 117 kW (400,000 BTU/h); 5 K (9 °F) hot-end approach | CO₂ side 130 bar / 1,885 psig, 120 °C |
| EX-201 A/B | CO₂ expander cylinders, double-acting | Ø100 mm × 400 mm stroke (3.94 × 15.75 in), 2 off | 130 bar, 120 °C |
| XV-201/202 | Admission / exhaust valves (4 per cylinder) | Hydraulically actuated poppets timed from ZT-201 | 130 bar, 120 °C |
| HX-102 | Recuperator (LP vapour → HP liquid) | 19.6 kW (66,900 BTU/h), effectiveness 0.80 | 130 bar both sides |
| HX-103 | Condenser (CO₂ → cooling water) | 110 kW (374,700 BTU/h), condensing at 20 °C (68 °F) | CO₂ 90 bar / 1,305 psig |
| V-201 | CO₂ liquid receiver | Holds the charge inventory; gives the pump suction head | 90 bar (PSV-202 set point) |
| P-201 | CO₂ feed pump, VFD (plunger or diaphragm type) | 44 L/min (11.7 gpm), 57 → 110 bar (831 → 1,595 psia); 5.9 kW shaft | 130 bar |
| HC-301 A/B | Hydraulic pump chambers in tandem with EX-201 | Max area 17.2 cm² (2.67 in²); stepped areas for Option B | 250 bar / 3,625 psi |
| A-301 | Bladder accumulator | Evens out the pulsing flow; ~20–40 L (5–10 gal) | 250 bar |
| RV-301 / PV-301 | Relief valve / proportional load valve | Relief set at 230 bar (3,340 psi) | — |
| HM-301 | Hydraulic consumer (motor, press, lift, etc.) | Up to ~12 kW at 207 bar (~5.3 kW if HM-302 also drives P-201) | — |
| T-301 / F-301 | Reservoir / return filter | ~100 L (26 gal), 10 µm return filter | Atmospheric |
03Cycle state points (Option B, 110 bar)
Properties from CoolProp (Span–Wagner equation of state for CO₂). Mass flow 0.591 kg/s (4,690 lb/h). Enthalpy reference: IIR (h = 200 kJ/kg for saturated liquid at 0 °C).
| # | Location | Pressure bar / psia | Temperature °C / °F | Enthalpy kJ/kg / BTU/lb | Density kg/m³ / lb/ft³ | Phase |
|---|---|---|---|---|---|---|
| 1 | Pump suction (receiver outlet) | 57.3 / 831 | 18.0 / 64.4 | 248.0 / 106.6 | 801 / 50.02 | subcooled liquid |
| 2 | Pump discharge | 110.0 / 1,595 | 26.4 / 79.5 | 257.9 / 110.9 | 822 / 51.31 | compressed liquid |
| 3 | Recuperator cold-side outlet | 110.0 / 1,595 | 37.1 / 98.7 | 291.2 / 125.2 | 721 / 45.00 | supercritical (liquid-like) |
| 4 | Gas-heater outlet / cylinder admission | 107.8 / 1,564 | 95.0 / 203.0 | 489.5 / 210.5 | 217 / 13.53 | supercritical |
| 5 | Cylinder exhaust | 58.4 / 848 | 47.7 / 117.8 | 467.0 / 200.8 | 133 / 8.29 | superheated vapour |
| 6 | Recuperator hot-side outlet | 58.4 / 848 | 29.7 / 85.5 | 433.8 / 186.5 | 163 / 10.20 | superheated vapour |
Heat and fluid flows
| Stream | Metric | Imperial |
|---|---|---|
| Fuel firing (wood) | 146.5 kW | 500,000 BTU/h |
| Heat to loop (80 % boiler) | 117.2 kW | 400,000 BTU/h |
| Hot water W1→W2 | 100→60 °C, 0.70 kg/s, 2.6 m³/h | 212→140 °F, 11.4 gpm |
| CO₂ mass flow | 0.591 kg/s · 2,128 kg/h | 4,690 lb/h |
| CO₂ liquid to pump (1) | 44.3 L/min | 11.7 gpm |
| CO₂ at cylinder inlet (4) | 2.73 L/s · 164 L/min | 5.8 ft³/min |
| CO₂ at cylinder exhaust (5) | 4.45 L/s · 267 L/min | 9.4 ft³/min |
| Recuperator duty | 19.6 kW | 66,900 BTU/h |
| Condenser duty | 109.8 kW | 374,700 BTU/h |
| Cooling water C | 15→18.5 °C, 7.5 kg/s, 27 m³/h | 59→65 °F, 119 gpm |
| Hydraulic oil H1 | 35.5 L/min at 207 bar | 9.4 gpm at 3,000 psi |
Energy balance: 117.2 kW heat + 5.9 kW pump work = 13.3 kW expander work + 109.8 kW rejected (closes within 0.1 kW). The cooling water heats up only 3.5 K because the condenser runs with a 2 K pinch to hold CO₂ condensing at 20 °C. Accepting a 22–23 °C condensing temperature would halve the cooling-water flow, at a cost of about 0.4–0.5 percentage points of efficiency.
04Expander: CO₂ cylinders driving hydraulic oil
How the piston expander is coupled to the hydraulic circuit, and why two options are analysed.
A free-piston CO₂ cylinder is joined directly to a hydraulic plunger, so the force on the CO₂ piston and the oil pressure are tied by a fixed area ratio. The hydraulic side wants a constant pressure (207 bar), so the CO₂ force should also be constant across the stroke. That leads to two ways of running the cylinder:
Option A: full-pressure admission. The inlet valve stays open for the whole stroke, so CO₂ at 107.8 bar pushes against 58.4 bar back pressure. The 49.4 bar (717 psi) net pressure acts on a 78.5 cm² piston, giving a constant force of 38.8 kN (8,720 lbf). That matches a 17.2 cm² (Ø46.8 mm / 1.84 in) plunger at 207 bar, after 8 % seal and friction loss. It is simple, self-regulating and robust. The penalty is that the cylinder is exhausted while still at full pressure, which loses about 9 % of the available work. A modelled 0.90 factor covers valve throttling and leakage.
Option B: cutoff and expansion. The inlet valve closes at about 61 % of the stroke and the CO₂ expands for the rest (volume ratio 1.63). Force falls from 38.8 kN to almost zero by the end of the stroke. The hydraulic side follows it with stepped (digital) plunger areas, such as three chambers switched by valves, or a crank and flywheel driving a rotary pump. Assuming 80 % indicated efficiency, it gives +9 % hydraulic power and +25 % net power, at the cost of more valves and controls.
Cylinder sizing
| Item | Option A | Option B |
|---|---|---|
| Cylinders | 2 × double-acting | 2 × double-acting |
| CO₂ bore × stroke | Ø100 × 400 mm · Ø3.94 × 15.75 in | |
| Swept CO₂ volume flow | 2.75 L/s · 5.8 cfm | 4.45 L/s · 9.4 cfm |
| Cycle rate | 13 cycles/min | 21 cycles/min |
| Mean piston speed | 0.17 m/s · 34 ft/min | 0.28 m/s · 56 ft/min |
| Peak rod force | 38.8 kN · 8,720 lbf | 38.8 kN · 8,720 lbf |
| Mean rod force | 38.8 kN · 8,720 lbf | 23.5 kN · 5,280 lbf |
| Hydraulic plunger area | 17.2 cm² · 2.67 in² | stepped, 17.2 → ~5 cm² |
| Oil delivered at 207 bar | 32.6 L/min · 8.6 gpm | 35.5 L/min · 9.4 gpm |
The low piston speeds keep valve losses and seal wear down. Cycle rate can be raised to shrink the cylinders, but each doubling adds valve-throttling loss.
05Power from a 500,000 BTU/h wood-fired burner
Where the heat goes, Option B, self-powered configuration.
Bar length is proportional to power. Values in kW, with hp or BTU/h in brackets. Plant parasitic loads (about 0.25 kW hot-water pump, 1.0 kW cooling-water pump or fan, 0.3–0.5 kW boiler draft fan and controls) come on top. They total roughly 1.5–2 kW of electricity unless the cooling water flows by gravity or from a well.
Why the efficiency is only about 5 %
The hot water drops from 100 to 60 °C, so heat arrives at an average of about 80 °C (353 K) and leaves at about 15 °C (288 K). The Carnot limit for that is about 18 %. The cycle reaches about 30 % of Carnot. That is normal for a small transcritical CO₂ cycle with a 100 °C source. Two features of CO₂ dominate:
- High pump work. Pumping CO₂ from 57 to 110 bar takes 48 % of the gross expander output. Feed-pump efficiency is the most important single assumption: raising it from 65 % to 80 % lifts net power from 5.3 to 6.6 kW (7.2 → 8.9 hp).
- Small pressure ratio. The cylinders work across only 1.85:1, so leakage, valve pressure drop and heat transfer in the cylinder matter. Tight, well-insulated cylinders and low-loss poppet valves are essential.
Sensitivity
| Case (117 kW heat, Option B) | Cycle η | Net hydraulic* |
|---|---|---|
| Design: 100 °C source / 15 °C water | 5.4 % | 5.3 kW · 7.2 hp |
| 120 °C source (248 °F) | 6.9 % | ≈ 7.1 kW · 9.5 hp |
| 150 °C source (302 °F, pressurised water) | 9.0 % | ≈ 9.5 kW · 12.7 hp |
| Winter cooling water 5 °C (41 °F) | 7.1 % | ≈ 7.3 kW · 9.8 hp |
| Summer cooling water 25 °C (77 °F) | 3.5 % | ≈ 3.0 kW · 4.0 hp |
| If 500,000 BTU/h is the boiler output (146.5 kW) | 5.4 % | 6.7 kW · 9.0 hp |
*Off-design net values are estimated by scaling the design-point split between gross power and pump power. Treat them as ±10 %.
06Control philosophy and safety
Control loops
- TIC-101: burner firing rate (draft fan or air damper) holds hot-water supply at 100 °C. A hot-water buffer tank (≥ 1,000 L / 260 gal) is recommended because a wood fire responds slowly.
- TV-101: 3-way valve holds boiler return ≥ 60 °C.
- PIC-201: the P-201 VFD sets CO₂ flow to hold the high side at 110 bar. The heater outlet temperature then follows the heat available.
- ZT-201 → PLC: piston position drives XV-201/202 timing (admission, cutoff, exhaust) and reverses the double-acting stroke. Option B also switches the hydraulic area steps.
- PIC-301: accumulator pressure. The PLC lowers the expander cycle rate or opens PV-301 to hand power to the load. RV-301 is the final protection.
- Start-up: circulate hot water, run P-201 on recirculation until stream 4 exceeds 80 °C, then enable the valve sequence. Use battery or hydraulic hand-pump assist for the first strokes.
Safety and code items
- CO₂ high side up to 130 bar (1,885 psig) design: PSV-201 on the heater/expander side, PSV-202 on receiver and low side (90 bar). Every isolatable liquid-CO₂ section needs thermal relief, because trapped liquid CO₂ expands sharply when it warms.
- In the EU this is a pressure system under the Pressure Equipment Directive 2014/68/EU; in the US, ASME BPVC Section VIII and B31.3 (B31.5 refrigeration practice). Hydraulic side per ISO 4413.
- CO₂ is an asphyxiant. Indoor installations need a CO₂ gas detector (alarm at 5,000 ppm), ventilation, and relief valves vented outdoors.
- Standstill: on a warm day the stopped system's pressure rises toward the CO₂ saturation pressure at ambient (about 64 bar at 25 °C; supercritical above 31 °C). Size the low side for this, or fit a small standstill condensing unit.
- Trips: PSHH-201 (high CO₂ pressure), TSHH-101 (boiler overheat, wood fire dump zone), LSLL-201 (receiver low level, pump dry-run), PSHH-301 (hydraulic overpressure), emergency stop.
- Wood boiler: overheat heat-dump loop (gravity-fed to a dump radiator) per the boiler manufacturer and EN 303-5 / UL 391.
07Conclusions
About 12 kW (16 hp) of hydraulic power, about 5 kW (7 hp) net, from 500,000 BTU/h of wood at 100 °C
- A transcritical CO₂ cycle between 100 °C water and 15 °C water works with a 110 bar high side and a 57 bar condensing pressure. Every component is within ordinary high-pressure hydraulic and CO₂-refrigeration practice.
- Coupling CO₂ pistons directly to hydraulic plungers avoids a crankshaft, a generator and a hydraulic pump. At about 21 cycles/min, two Ø100 × 400 mm cylinders deliver 35 L/min (9.4 gpm) of oil at 207 bar (3,000 psi).
- The main losses are the CO₂ feed pump (48 % back-work ratio) and the low source temperature. Pump efficiency, valve losses and leakage decide whether the net figure is 4 or 7 kW.
- For a true waste-heat application at 100 °C, the system is a credible, simple way to get hydraulic power without an electrical conversion step. When wood is the main fuel, raising the loop to 150 °C is the most effective upgrade (≈ +80 % net power).
Basis and assumptions
| Parameter | Value used |
|---|---|
| Boiler (wood → hot water) efficiency | 80 % (500,000 BTU/h taken as fuel firing rate) |
| Hot-water supply / return | 100 °C / 60 °C (212 / 140 °F); heater hot-end approach 5 K (9 °F) |
| Cooling water / condensing | 15 °C in (59 °F); condensing 20 °C (68 °F), 57.3 bar; liquid subcooled to 18 °C |
| Expander indicated efficiency | Option B 80 % isentropic; Option A 90 % of ideal full-admission work |
| CO₂ piston → hydraulic transfer | 92 % (seals, rod friction, check valves) |
| CO₂ feed pump | 65 % isentropic; motor 90 % (electric) or hydraulic motor 85 % |
| Recuperator effectiveness / pressure drops | 0.80; 2 % pressure loss in each of heater and low-side path |
| Hydraulic system pressure | 207 bar (3,000 psi) |
| Property data | CoolProp 8 (Span–Wagner CO₂, IAPWS water) |
This is a preliminary feasibility analysis, not a certified design. Vessel, piping and relief sizing must be confirmed by detailed design to the applicable codes.