Transcritical CO₂ Cylinder-Expander Waste-Heat-to-Hydraulic System — 100 C Source, 15 C Sink, 500,000 BTU/h Wood Burner | Infinity Turbine LLC

Engineering analysis · Infinity Turbine LLC · November 2026

Thermodynamic analysis, P&ID, state points, flows, pressures and power output for a CO₂ cycle heated by 100 °C (212 °F) hot water and cooled by 15 °C (59 °F) water. The CO₂ drives pistons that pump hydraulic oil directly. The heat source is a 500,000 BTU/h wood-fired burner.

12.2 kW
Gross hydraulic power · 16.4 hp (Option B)
5.3 kW
Net hydraulic after CO₂ feed pump · 7.2 hp
35.5 L/min
Oil flow at 207 bar · 9.4 gpm at 3,000 psi
5.4 %
Cycle efficiency on 117 kW (400,000 BTU/h) heat

01Summary

What the system is, what it can produce, and the main design decisions.

Concept. CO₂ is pumped as a liquid to about 110 bar (1,595 psia), above its critical pressure of 73.8 bar. It is heated by 100 °C water to 95 °C (203 °F) and admitted to double-acting cylinders. Each CO₂ piston is joined by a rod to a hydraulic plunger. The plunger draws oil from the reservoir and pushes it through check valves into an accumulator at 207 bar (3,000 psi). The exhaust CO₂ (about 58 bar, 48 °C) gives up heat in a recuperator. It is then condensed at 20 °C / 57 bar (68 °F / 831 psia) with 15 °C cooling water and pumped back to high pressure.

Why CO₂. With a 15 °C sink, CO₂ condenses below its 31 °C critical temperature. That allows a real liquid pump and a transcritical cycle. The working pressures are high, so the gas is dense and a short-stroke piston expander stays compact. The pressures also fall naturally in the range of industrial hydraulic components.

Power. The 500,000 BTU/h burner delivers about 117 kW (400,000 BTU/h) to the hot-water loop at 80 % boiler efficiency. That heat gives 11.2–12.2 kW (15–16 hp) of gross hydraulic power. After the CO₂ feed pump is driven, 4.3–5.3 kW (5.7–7.2 hp) of net hydraulic power is left over.

Headline results (design point, 110 bar)

Option A
full admission
Option B
cutoff + expansion
Heat to CO₂117.2 kW
400,000 BTU/h
117.2 kW
400,000 BTU/h
CO₂ mass flow0.596 kg/s
4,730 lb/h
0.591 kg/s
4,690 lb/h
Expander indicated work12.2 kW · 16.4 hp13.3 kW · 17.8 hp
Gross hydraulic out11.2 kW · 15.1 hp12.2 kW · 16.4 hp
CO₂ feed pump (shaft)5.9 kW · 7.9 hp5.9 kW · 7.9 hp
Net hydraulic, self-powered*4.3 kW · 5.7 hp5.3 kW · 7.2 hp
Oil flow at 207 bar / 3,000 psi32.6 L/min · 8.6 gpm35.5 L/min · 9.4 gpm
Cycle efficiency4.5 %5.4 %
Fuel → net hydraulic2.9 %3.6 %

*CO₂ feed pump driven by a hydraulic motor (85 % efficient) from the system's own output. If the pump is driven by an electric motor instead, the full gross hydraulic power is available and the pump draws about 6.5 kW of electricity.

02Piping & instrumentation diagram

Three circuits: pressurised hot water, transcritical CO₂, and 207 bar hydraulic oil. Stream numbers refer to the state table in Section 03.

HEAT SOURCE · HOT-WATER LOOP TRANSCRITICAL CO₂ LOOP HYDRAULIC POWER CIRCUIT · 207 bar / 3,000 psi PLC-101 Supervisory control • Valve timing XV-201/202 from piston position ZT-201 • CO₂ high-side pressure PIC-201 → P-201 VFD speed • Burner firing TIC-101 (100 °C supply), return ≥ 60 °C (TV-101) • Accumulator pressure PIC-301 → expander cycle rate / load • Trips: PSHH-201, TSHH-101, LSLL-201, PSHH-301, ESD B-101 Wood-fired boiler 500,000 BTU/h (146.5 kW) firing ≈ 400,000 BTU/h (117 kW) to loop flue PSV-101 P-1012.6 m³/h · 11 gpm TV-101 return-temp protection ET-101 TTTT-101 W1 W2 HX-101CO₂ gas heater 117 kW XV-201 PSV-201 PTPT/TT-201 4 EX-201 A/B CO₂ expanders, 2× double-acting Ø100×400 mm (3.9×15.75 in)≈ 21 cycles/min HC-301 A/B hydraulic pump chambers stepped areas,max 17.2 cm² (2.67 in²) ZTZT-201 XV-202 5 HX-102Recuperator 19.6 kW 6 HX-103 condenser110 kW · 20 °C (68 °F) / 57 bar 15 °C / 59 °F in18.5 °C / 65 °F out C CW 27 m³/h · 119 gpm V-201CO₂ receiver LT PSV-202 1 P-201feed pump, VFD 2 3 PICPIC-201 CV-302 H1 A-301accumulator, N₂ precharge PTPT-301 RV-301 PV-301 HM-301hydraulic load F-301 T-301 reservoir H2 CV-301 option: HM-302 → P-201 Legend Hot water 100 °C → 60 °C CO₂ high side 110 bar (1,595 psia) CO₂ low side 57–58 bar (831–848 psia) Cooling water 15 °C Hydraulic oil 207 bar (3,000 psi) 4stream no.
P&ID — transcritical CO₂ cylinder-expander system, heated by hot water and producing hydraulic power. Tags follow ISA-5.1 style: B boiler, HX heat exchanger, P pump, XV on/off valve, TV temperature valve, PSV pressure-safety valve, CV check valve, RV relief valve, A accumulator, T tank, PT/TT/LT/ZT pressure, temperature, level and position transmitters, PIC pressure-indicating controller.

Equipment list

TagServiceDuty / sizeDesign conditions
B-101Wood-fired hot-water boiler500,000 BTU/h (146.5 kW) firing; ~400,000 BTU/h (117 kW) to the loop110 °C / 230 °F; 6 bar(g) / 87 psig
P-101Hot-water circulation pump2.6 m³/h (11.4 gpm), ~1.5 bar (22 psi) head; ~0.25 kW110 °C; 6 bar(g)
TV-1013-way return-temperature valveKeeps boiler return ≥ 60 °C (140 °F) against creosote and condensation—
ET-101Expansion tankLoop pressurised to ~3 bar(g) (44 psig) so 100 °C water stays liquid6 bar(g)
HX-101CO₂ gas heater (water → CO₂), counterflow117 kW (400,000 BTU/h); 5 K (9 °F) hot-end approachCO₂ side 130 bar / 1,885 psig, 120 °C
EX-201 A/BCO₂ expander cylinders, double-actingØ100 mm × 400 mm stroke (3.94 × 15.75 in), 2 off130 bar, 120 °C
XV-201/202Admission / exhaust valves (4 per cylinder)Hydraulically actuated poppets timed from ZT-201130 bar, 120 °C
HX-102Recuperator (LP vapour → HP liquid)19.6 kW (66,900 BTU/h), effectiveness 0.80130 bar both sides
HX-103Condenser (CO₂ → cooling water)110 kW (374,700 BTU/h), condensing at 20 °C (68 °F)CO₂ 90 bar / 1,305 psig
V-201CO₂ liquid receiverHolds the charge inventory; gives the pump suction head90 bar (PSV-202 set point)
P-201CO₂ feed pump, VFD (plunger or diaphragm type)44 L/min (11.7 gpm), 57 → 110 bar (831 → 1,595 psia); 5.9 kW shaft130 bar
HC-301 A/BHydraulic pump chambers in tandem with EX-201Max area 17.2 cm² (2.67 in²); stepped areas for Option B250 bar / 3,625 psi
A-301Bladder accumulatorEvens out the pulsing flow; ~20–40 L (5–10 gal)250 bar
RV-301 / PV-301Relief valve / proportional load valveRelief set at 230 bar (3,340 psi)—
HM-301Hydraulic consumer (motor, press, lift, etc.)Up to ~12 kW at 207 bar (~5.3 kW if HM-302 also drives P-201)—
T-301 / F-301Reservoir / return filter~100 L (26 gal), 10 µm return filterAtmospheric

03Cycle state points (Option B, 110 bar)

Properties from CoolProp (Span–Wagner equation of state for CO₂). Mass flow 0.591 kg/s (4,690 lb/h). Enthalpy reference: IIR (h = 200 kJ/kg for saturated liquid at 0 °C).

#LocationPressure
bar / psia
Temperature
°C / °F
Enthalpy
kJ/kg / BTU/lb
Density
kg/m³ / lb/ft³
Phase
1Pump suction (receiver outlet)57.3 / 83118.0 / 64.4248.0 / 106.6801 / 50.02subcooled liquid
2Pump discharge110.0 / 1,59526.4 / 79.5257.9 / 110.9822 / 51.31compressed liquid
3Recuperator cold-side outlet110.0 / 1,59537.1 / 98.7291.2 / 125.2721 / 45.00supercritical (liquid-like)
4Gas-heater outlet / cylinder admission107.8 / 1,56495.0 / 203.0489.5 / 210.5217 / 13.53supercritical
5Cylinder exhaust58.4 / 84847.7 / 117.8467.0 / 200.8133 / 8.29superheated vapour
6Recuperator hot-side outlet58.4 / 84829.7 / 85.5433.8 / 186.5163 / 10.20superheated vapour
30 40 50 60 80 100 120 150 200 250 300 350 400 450 500 550 Specific enthalpy h, kJ/kg (BTU/lb = kJ/kg × 0.430) Pressure, bar (log) — psia = bar × 14.5 two-phase critical point 31 °C / 73.8 bar 95 °C (203 °F) 60 °C 31 °C State 1: h 248.0 kJ/kg, 57.3 bar 1 State 2: h 257.9 kJ/kg, 110.0 bar 2 State 3: h 291.2 kJ/kg, 110.0 bar 3 State 4: h 489.5 kJ/kg, 107.8 bar 4 State 5: h 467.0 kJ/kg, 58.4 bar 5 State 6: h 433.8 kJ/kg, 58.4 bar 6 heat input from hot water (HX-101) condenser + recuperator
CO₂ pressure–enthalpy diagram with the design cycle: 1→2 pump, 2→3 recuperator (cold side), 3→4 gas heater, 4→5 cylinder expansion, 5→6 recuperator (hot side), 6→1 desuperheat, condense and subcool.

Heat and fluid flows

StreamMetricImperial
Fuel firing (wood)146.5 kW500,000 BTU/h
Heat to loop (80 % boiler)117.2 kW400,000 BTU/h
Hot water W1→W2100→60 °C, 0.70 kg/s, 2.6 m³/h212→140 °F, 11.4 gpm
CO₂ mass flow0.591 kg/s · 2,128 kg/h4,690 lb/h
CO₂ liquid to pump (1)44.3 L/min11.7 gpm
CO₂ at cylinder inlet (4)2.73 L/s · 164 L/min5.8 ft³/min
CO₂ at cylinder exhaust (5)4.45 L/s · 267 L/min9.4 ft³/min
Recuperator duty19.6 kW66,900 BTU/h
Condenser duty109.8 kW374,700 BTU/h
Cooling water C15→18.5 °C, 7.5 kg/s, 27 m³/h59→65 °F, 119 gpm
Hydraulic oil H135.5 L/min at 207 bar9.4 gpm at 3,000 psi

Energy balance: 117.2 kW heat + 5.9 kW pump work = 13.3 kW expander work + 109.8 kW rejected (closes within 0.1 kW). The cooling water heats up only 3.5 K because the condenser runs with a 2 K pinch to hold CO₂ condensing at 20 °C. Accepting a 22–23 °C condensing temperature would halve the cooling-water flow, at a cost of about 0.4–0.5 percentage points of efficiency.

04Expander: CO₂ cylinders driving hydraulic oil

How the piston expander is coupled to the hydraulic circuit, and why two options are analysed.

A free-piston CO₂ cylinder is joined directly to a hydraulic plunger, so the force on the CO₂ piston and the oil pressure are tied by a fixed area ratio. The hydraulic side wants a constant pressure (207 bar), so the CO₂ force should also be constant across the stroke. That leads to two ways of running the cylinder:

Option A: full-pressure admission. The inlet valve stays open for the whole stroke, so CO₂ at 107.8 bar pushes against 58.4 bar back pressure. The 49.4 bar (717 psi) net pressure acts on a 78.5 cm² piston, giving a constant force of 38.8 kN (8,720 lbf). That matches a 17.2 cm² (Ø46.8 mm / 1.84 in) plunger at 207 bar, after 8 % seal and friction loss. It is simple, self-regulating and robust. The penalty is that the cylinder is exhausted while still at full pressure, which loses about 9 % of the available work. A modelled 0.90 factor covers valve throttling and leakage.

Option B: cutoff and expansion. The inlet valve closes at about 61 % of the stroke and the CO₂ expands for the rest (volume ratio 1.63). Force falls from 38.8 kN to almost zero by the end of the stroke. The hydraulic side follows it with stepped (digital) plunger areas, such as three chambers switched by valves, or a crank and flywheel driving a rotary pump. Assuming 80 % indicated efficiency, it gives +9 % hydraulic power and +25 % net power, at the cost of more valves and controls.

Recommendation: build Option A first to prove the valve gear, seals, CO₂ pump and control. Add the stepped hydraulic areas of Option B as a later upgrade on the same cylinders.
40 50 60 70 80 90 100 110 0% 20% 40% 60% 80% 100% Piston stroke, % of swept volume CO₂ pressure, bar Option A — full-pressure admission (no expansion), 110 bar Option B — cutoff at 61% then expansion exhaust / back pressure 58.4 bar (848 psia) admission 107.8 bar (1564 psia) Option B (expansion)Option A (full admission)
Indicator (pressure–stroke) diagram for one CO₂ cylinder stroke. The enclosed area is the work per unit of swept volume. Option B gets more work out of each kilogram of CO₂, but needs a larger swept volume and a force on the hydraulic side that changes over the stroke.

Cylinder sizing

ItemOption AOption B
Cylinders2 × double-acting2 × double-acting
CO₂ bore × strokeØ100 × 400 mm · Ø3.94 × 15.75 in
Swept CO₂ volume flow2.75 L/s · 5.8 cfm4.45 L/s · 9.4 cfm
Cycle rate13 cycles/min21 cycles/min
Mean piston speed0.17 m/s · 34 ft/min0.28 m/s · 56 ft/min
Peak rod force38.8 kN · 8,720 lbf38.8 kN · 8,720 lbf
Mean rod force38.8 kN · 8,720 lbf23.5 kN · 5,280 lbf
Hydraulic plunger area17.2 cm² · 2.67 in²stepped, 17.2 → ~5 cm²
Oil delivered at 207 bar32.6 L/min · 8.6 gpm35.5 L/min · 9.4 gpm

The low piston speeds keep valve losses and seal wear down. Cycle rate can be raised to shrink the cylinders, but each doubling adds valve-throttling loss.

05Power from a 500,000 BTU/h wood-fired burner

Where the heat goes, Option B, self-powered configuration.

Wood fuel firing
146.5 kW (500,000 BTU/h)
Heat to hot-water loop
117.2 kW (400,000 BTU/h)
Boiler / flue loss
29.3 kW (100,000 BTU/h)
Rejected in condenser
109.8 kW (374,700 BTU/h)
Expander indicated work
13.3 kW (17.8 hp)
Gross hydraulic power
12.2 kW (16.4 hp)
CO₂ pump drive (via HM-302)
6.9 kW (9.3 hp)
Net hydraulic power
5.3 kW (7.2 hp)

Bar length is proportional to power. Values in kW, with hp or BTU/h in brackets. Plant parasitic loads (about 0.25 kW hot-water pump, 1.0 kW cooling-water pump or fan, 0.3–0.5 kW boiler draft fan and controls) come on top. They total roughly 1.5–2 kW of electricity unless the cooling water flows by gravity or from a well.

Why the efficiency is only about 5 %

The hot water drops from 100 to 60 °C, so heat arrives at an average of about 80 °C (353 K) and leaves at about 15 °C (288 K). The Carnot limit for that is about 18 %. The cycle reaches about 30 % of Carnot. That is normal for a small transcritical CO₂ cycle with a 100 °C source. Two features of CO₂ dominate:

  • High pump work. Pumping CO₂ from 57 to 110 bar takes 48 % of the gross expander output. Feed-pump efficiency is the most important single assumption: raising it from 65 % to 80 % lifts net power from 5.3 to 6.6 kW (7.2 → 8.9 hp).
  • Small pressure ratio. The cylinders work across only 1.85:1, so leakage, valve pressure drop and heat transfer in the cylinder matter. Tight, well-insulated cylinders and low-loss poppet valves are essential.

Sensitivity

2% 4% 6% 8% 10% 80 90 100 110 120 150 Heat-source (hot water) temperature, °C Cycle efficiency, % 80: 3.9% 3.9% 90: 4.7% 4.7% 100: 5.4% 5.4% 110: 6.2% 6.2% 120: 6.9% 6.9% 150: 9.0% 9.0%
Hot-water supply temperature (CO₂ 5 K below it, high pressure re-optimised). Design point filled.
2% 4% 6% 8% 5 10 15 20 25 Cooling-water temperature, °C Cycle efficiency, % 5: 7.1% 7.1% 10: 6.3% 6.3% 15: 5.4% 5.4% 20: 4.5% 4.5% 25: 3.5% 3.5%
Cooling-water temperature (condensing 5 K above it).
Case (117 kW heat, Option B)Cycle ηNet hydraulic*
Design: 100 °C source / 15 °C water5.4 %5.3 kW · 7.2 hp
120 °C source (248 °F)6.9 %≈ 7.1 kW · 9.5 hp
150 °C source (302 °F, pressurised water)9.0 %≈ 9.5 kW · 12.7 hp
Winter cooling water 5 °C (41 °F)7.1 %≈ 7.3 kW · 9.8 hp
Summer cooling water 25 °C (77 °F)3.5 %≈ 3.0 kW · 4.0 hp
If 500,000 BTU/h is the boiler output (146.5 kW)5.4 %6.7 kW · 9.0 hp

*Off-design net values are estimated by scaling the design-point split between gross power and pump power. Treat them as ±10 %.

Design note for the wood burner. A wood fire burns at more than 1,000 °C. Limiting the system to 100 °C water is the right choice when the target application is genuine waste heat, such as engine jacket water, process cooling or flue-gas economisers, and the wood burner is only a test or backup heat source. If the wood burner will be the main heat source, a pressurised hot-water or thermal-oil loop at 150 °C would nearly double the hydraulic output from the same wood. CO₂ high pressure would rise to about 145 bar.

06Control philosophy and safety

Control loops

  • TIC-101: burner firing rate (draft fan or air damper) holds hot-water supply at 100 °C. A hot-water buffer tank (≥ 1,000 L / 260 gal) is recommended because a wood fire responds slowly.
  • TV-101: 3-way valve holds boiler return ≥ 60 °C.
  • PIC-201: the P-201 VFD sets CO₂ flow to hold the high side at 110 bar. The heater outlet temperature then follows the heat available.
  • ZT-201 → PLC: piston position drives XV-201/202 timing (admission, cutoff, exhaust) and reverses the double-acting stroke. Option B also switches the hydraulic area steps.
  • PIC-301: accumulator pressure. The PLC lowers the expander cycle rate or opens PV-301 to hand power to the load. RV-301 is the final protection.
  • Start-up: circulate hot water, run P-201 on recirculation until stream 4 exceeds 80 °C, then enable the valve sequence. Use battery or hydraulic hand-pump assist for the first strokes.

Safety and code items

  • CO₂ high side up to 130 bar (1,885 psig) design: PSV-201 on the heater/expander side, PSV-202 on receiver and low side (90 bar). Every isolatable liquid-CO₂ section needs thermal relief, because trapped liquid CO₂ expands sharply when it warms.
  • In the EU this is a pressure system under the Pressure Equipment Directive 2014/68/EU; in the US, ASME BPVC Section VIII and B31.3 (B31.5 refrigeration practice). Hydraulic side per ISO 4413.
  • CO₂ is an asphyxiant. Indoor installations need a CO₂ gas detector (alarm at 5,000 ppm), ventilation, and relief valves vented outdoors.
  • Standstill: on a warm day the stopped system's pressure rises toward the CO₂ saturation pressure at ambient (about 64 bar at 25 °C; supercritical above 31 °C). Size the low side for this, or fit a small standstill condensing unit.
  • Trips: PSHH-201 (high CO₂ pressure), TSHH-101 (boiler overheat, wood fire dump zone), LSLL-201 (receiver low level, pump dry-run), PSHH-301 (hydraulic overpressure), emergency stop.
  • Wood boiler: overheat heat-dump loop (gravity-fed to a dump radiator) per the boiler manufacturer and EN 303-5 / UL 391.

07Conclusions

About 12 kW (16 hp) of hydraulic power, about 5 kW (7 hp) net, from 500,000 BTU/h of wood at 100 °C

  • A transcritical CO₂ cycle between 100 °C water and 15 °C water works with a 110 bar high side and a 57 bar condensing pressure. Every component is within ordinary high-pressure hydraulic and CO₂-refrigeration practice.
  • Coupling CO₂ pistons directly to hydraulic plungers avoids a crankshaft, a generator and a hydraulic pump. At about 21 cycles/min, two Ø100 × 400 mm cylinders deliver 35 L/min (9.4 gpm) of oil at 207 bar (3,000 psi).
  • The main losses are the CO₂ feed pump (48 % back-work ratio) and the low source temperature. Pump efficiency, valve losses and leakage decide whether the net figure is 4 or 7 kW.
  • For a true waste-heat application at 100 °C, the system is a credible, simple way to get hydraulic power without an electrical conversion step. When wood is the main fuel, raising the loop to 150 °C is the most effective upgrade (≈ +80 % net power).

Basis and assumptions

ParameterValue used
Boiler (wood → hot water) efficiency80 % (500,000 BTU/h taken as fuel firing rate)
Hot-water supply / return100 °C / 60 °C (212 / 140 °F); heater hot-end approach 5 K (9 °F)
Cooling water / condensing15 °C in (59 °F); condensing 20 °C (68 °F), 57.3 bar; liquid subcooled to 18 °C
Expander indicated efficiencyOption B 80 % isentropic; Option A 90 % of ideal full-admission work
CO₂ piston → hydraulic transfer92 % (seals, rod friction, check valves)
CO₂ feed pump65 % isentropic; motor 90 % (electric) or hydraulic motor 85 %
Recuperator effectiveness / pressure drops0.80; 2 % pressure loss in each of heater and low-side path
Hydraulic system pressure207 bar (3,000 psi)
Property dataCoolProp 8 (Span–Wagner CO₂, IAPWS water)

This is a preliminary feasibility analysis, not a certified design. Vessel, piping and relief sizing must be confirmed by detailed design to the applicable codes.