This follows on from the 100 °C / 15 °C study. Cooling is now 5 °C (41 °F) creek or glycol water, and the heat comes from a 500,000 BTU/h log boiler whose flue gas reaches 800 °C (1,472 °F). The CO₂ cylinders drive hydraulic plungers that power the wash plant directly.

39.2 kW
Net hydraulic power, 800 °C case · 52.6 hp
50.7 kW
Gross hydraulic power · 68 hp
147 L/min
Oil at 207 bar · 38.8 gpm at 3,000 psi
26.8 %
Wood → net hydraulic (was 3.6 % at 100 °C / 15 °C)

01Answer in brief

What is the optimum heat source? A log boiler already burns at well over 800 °C. The best choice is therefore to put the CO₂ heater coil directly in the flue gas, not to heat water or thermal oil first. Every intermediate loop caps the CO₂ temperature, and in this cycle each extra 100 °C of CO₂ inlet temperature adds about 2–8 kW of net hydraulic power, with the largest gains at the low end (Section 03).

How hot should the CO₂ be? On thermodynamics alone, as hot as possible. In practice the gains shrink above about 500 °C while cost and risk climb steeply: nickel-alloy heater tubes, 300 bar design, and piston rings and valves running far above the temperatures used in steam engines. The recommended engineering optimum is CO₂ at 450–550 °C and 200–250 bar, heated directly by flue gas. That gives about 32–35 kW (43–47 hp) net hydraulic, compared with 39 kW at the 700 °C limit.

The full 800 °C case: with CO₂ heated to 700 °C at 300 bar (a 100 K approach to the 800 °C flue gas), the system delivers 50.7 kW gross and 39.2 kW net hydraulic power. That is 147 L/min (38.8 gpm) of oil at 207 bar (3,000 psi), about 7 times the 100 °C system's output from the same wood.

Performance from 500,000 BTU/h of wood (146.5 kW)

CaseNet hydraulicWood → net
Previous study: 100 °C water, 15 °C cooling5.3 kW · 7.2 hp3.6 %
100 °C water, 5 °C cooling6.9 kW · 9.3 hp4.7 %
Thermal oil 320 °C → CO₂ 300 °C, 200 bar22.4 kW · 30 hp15.3 %
Recommended: direct-fired, CO₂ 500 °C, 200 bar32.2 kW · 43 hp22.0 %
800 °C flue: CO₂ 700 °C, 300 bar39.2 kW · 52.6 hp26.8 %

Net = hydraulic output after the CO₂ feed pump is driven by a hydraulic motor taken from the same output. Assumptions are listed in Section 09.

02Effect of 5 °C cooling and the Yukon setting

With 5 °C (41 °F) cooling water and a 5 K approach, CO₂ condenses at 10 °C and 45.0 bar (50 °F, 653 psia), compared with 20 °C and 57.3 bar before. The lower back pressure raises the expander pressure ratio and cuts pump work per kilogram. At the original 100 °C source this alone lifts net output by about 30 % (5.3 → 6.9 kW). The colder sink matters even more once the CO₂ is hot: at 700 °C the cylinders expand across a 6.4 : 1 pressure ratio.

Season and cooling source. Yukon placer mining runs mainly May to September, when air can reach 25–30 °C (77–86 °F). In summer, 5 °C cooling therefore has to come from creek water or groundwater (typically 2–8 °C) through a plate heat exchanger, with a closed glycol loop on the CO₂ condenser side so the condenser never sees silt or freezing. A glycol dry cooler covers shoulder seasons and winter operation, down to −40 °C ambient.

Cold-climate design points

  • Hold condensing at 8–10 °C with a 3-way glycol valve. Do not let CO₂ condense colder in winter: pump suction head and liquid density change, and the triple point is −56.6 °C (−70 °F).
  • Standstill pressure: stopped at −30 °C, the CO₂ sits at about 14 bar as liquid. On a 25 °C summer day it reaches about 64 bar, and above 31 °C it becomes supercritical. Design the low side for 90 bar, or fit a small standstill chiller.
  • Heated hydraulic reservoir and oil cooler on the same glycol loop. Use low-pour-point hydraulic oil (ISO VG 32 arctic grade) for −40 °C cold starts.
  • Air preheater (HX-104) protects against cold combustion air and recovers 53 kW (182,000 BTU/h) of flue heat.

03Choosing the heat source

For each heat-transfer arrangement, the CO₂ high pressure is optimised (capped at 200 or 300 bar), the recuperator is pinch-limited (10 K), and the boiler efficiency is calculated from the flue-gas temperature that the heater can actually reach. The flue enters at 800 °C, and an air preheater takes the stack down to 150 °C.

pressurised water thermal oil direct-fired CO₂ heater Ni-alloy, research zone 0 10 20 30 40 100 200 300 400 500 600 700 CO₂ temperature at cylinder inlet, °C (°F = °C × 1.8 + 32) Net hydraulic power, kW (hp = kW × 1.341) 300 bar max, 100 °C: 7.3 kW 300 bar max, 150 °C: 11.4 kW 300 bar max, 200 °C: 15.3 kW 300 bar max, 250 °C: 19.0 kW 300 bar max, 300 °C: 22.4 kW 300 bar max, 350 °C: 25.6 kW 300 bar max, 400 °C: 28.5 kW 300 bar max, 450 °C: 31.0 kW 300 bar max, 500 °C: 33.3 kW 300 bar max, 550 °C: 35.3 kW 300 bar max, 600 °C: 36.9 kW 300 bar max, 650 °C: 38.2 kW 300 bar max, 700 °C: 39.2 kW 300 bar max: 39.2 kW 200 bar max, 100 °C: 7.3 kW 200 bar max, 150 °C: 11.4 kW 200 bar max, 200 °C: 15.3 kW 200 bar max, 250 °C: 19.0 kW 200 bar max, 300 °C: 22.4 kW 200 bar max, 350 °C: 25.5 kW 200 bar max, 400 °C: 28.1 kW 200 bar max, 450 °C: 30.3 kW 200 bar max, 500 °C: 32.2 kW 200 bar max, 550 °C: 33.8 kW 200 bar max, 600 °C: 35.1 kW 200 bar max, 650 °C: 36.1 kW 200 bar max, 700 °C: 36.7 kW 200 bar max: 36.7 kW 7.3 kW 22.4 kW 33.3 kW 300 bar max200 bar max
Net hydraulic power versus CO₂ cylinder-inlet temperature from 500,000 BTU/h of wood, with 5 °C cooling. Shaded bands show which heat-transfer method can reach each temperature. Gains fall from about 3.8 kW per 50 °C below 300 °C to about 1 kW per 50 °C above 600 °C.
Heat source arrangementCO₂ in
°C / °F
High side
bar / psia
Boiler η
(wood → CO₂)
Cycle ηGross hyd.
kW / hp
CO₂ pump
kW
Net hyd.
kW / hp
Wood → net
Pressurised hot water, 100 °C loop95 / 203100 / 1,45078 %6.1 %12.1 / 164.46.9 / 9.34.7 %
Pressurised hot water, 180 °C loop (~15 bar)175 / 347140 / 2,03078 %11.7 %21.3 / 296.713.4 / 189.1 %
Thermal oil, 320 °C loop300 / 572200 / 2,90078 %19.6 %33.4 / 459.322.4 / 3015.3 %
Direct-fired CO₂ heater (recommended)500 / 932200 / 2,90076 %28.8 %41.5 / 567.932.2 / 4322.0 %
Direct-fired, 800 °C flue, 200 bar cap700 / 1,292200 / 2,90071 %35.5 %44.5 / 606.636.7 / 4925.1 %
Direct-fired, 800 °C flue, 300 bar700 / 1,292300 / 4,35072 %37.4 %50.7 / 689.839.2 / 5326.8 %

Why direct-firing wins

Water above 180 °C needs heavy pressure vessels. Thermal oil is limited to about 320–340 °C and degrades if it overheats in a wood firebox. Neither can use the 800 °C the fire provides. A CO₂ coil in the flue gas avoids a whole heat-transfer step and its temperature loss, and CO₂ is a stable, non-flammable heat carrier. As the CO₂ gets hotter, boiler efficiency falls slightly (78 → 72 %) because the gas leaving the coil is hotter. The air preheater recovers most of that.

Why stop at 450–550 °C in practice

Up to about 550 °C the CO₂ heater can be stainless 347H or 800H tube and the cylinders can follow superheated-steam-engine practice: cast steel, graphite or carbon piston rings, and Stellite-faced poppet valves. Going to 700 °C means Inconel 617/740H tubing, ceramic or carbon rings, and 300 bar at temperatures where creep governs. All that buys only +7 kW (+22 %). For a remote Yukon site, reliability and field repair matter more than the last few kW.

04P&ID — direct-fired 800 °C configuration

Log boiler with an in-flue CO₂ heater and air preheater; compound (HP + LP) CO₂ cylinders in tandem with stepped hydraulic plungers; recuperator; creek-water/glycol condenser; and the hydraulic power circuit feeding the wash plant.

LOG BOILER · FLUE GAS 800 °C TRANSCRITICAL CO₂ · 300 bar / 700 °C HYDRAULIC CIRCUIT · 207 bar / 3,000 psi PLC-101 Control & protection • TIC-101: FD/ID fans + dampers hold 800 °C flue · TIC-201: P-201 VFD holds 700 °C CO₂ outlet • PIC-201: high side 300 bar via cylinder cutoff / cycle rate · PIC-301: accumulator pressure → hydraulic step selection • HP-coil protection: low CO₂ flow (FSLL-201) → open PV-202 bypass, close air dampers, start dump cooler HX-105 • Trips: PSHH-201, TSHH-201 (coil skin), LSLL-201, PSHH-301, CO₂ gas detector AE-401, ESD Design point (800 °C flue, 500,000 BTU/h logs) Fuel 146.5 kW · heat to CO₂ 105.1 kW (71.7 %) · CO₂ 0.229 kg/s (1,820 lb/h) Expander 55.1 kW · hydraulic gross 50.7 kW (68 hp) · CO₂ pump 9.8 kW Net hydraulic 39.2 kW (52.6 hp) · 147 L/min (38.8 gpm) at 207 bar Condensing 10 °C / 45 bar (653 psia) · creek / glycol cooling 5 °C (41 °F) B-101 log boiler firebox refractory-lined, 500,000 BTU/h (146.5 kW) · ≈ 35 kg/h wood loading door HX-101 CO₂ heater, 105 kWInconel 617 coil flue 800 → 369 °C(1,472 → 696 °F) HX-104air preheater369→150 °C, 53 kW TTTT-101 F-102 ID fanstack 150 °C F-101 FD fan ambient air −40…+25 °C hot air≈ 260 °C TV-101 HX-105CO₂ dump cooler(air, fail-safe) 4 TTTT/PT-201 PSV-201 XV-201 EX-201 HPØ72×400 mm EX-202 LP · Ø107×400 mm DP-201cooleddistance piece V-202IP receiver 116 bar XV-203 4a XV-204 5 PV-202 bypassdump HX-102 114 kWrecuperator, PCHE 6 HX-103condenser 60 kW10 °C / 45 bar glycol in 5 °C (41 °F) out 8 °C · 17 m³/h · 75 gpm ← creek-water HX / dry cooler V-201 receiver LT 1 P-201 CO₂ pump45 → 300 bar, 15.6 L/min (4.1 gpm), VFD 2 3 CO₂ in 339 °C HC-301 stepped plungers 3 areas 15/30/60 cm²(2.3/4.7/9.4 in²)DV-301 switching CV-302 H1 A-301 PICPIC-301 RV-301 HM-301trommel / wash plant HM-302sluice water pump HM-303drives P-201 (11.5 kW) F-301 oil cooler T-301 reservoir (heated) H2 CV-301 Legend Flue gas 800 → 150 °C Combustion air CO₂ high side 300 bar (4,350 psia) CO₂ intermediate 116 bar (1,685 psia) CO₂ low side 45–46 bar (653–666 psia) Glycol / creek water 5 °C Hydraulic oil
P&ID tags: B boiler, F fan, HX heat exchanger, EX expander cylinder, HC hydraulic plunger chamber, DP distance piece, V vessel, P pump, XV/PV/TV on-off, pressure and temperature control valves, PSV/RV safety and relief valves, CV check valve, HM hydraulic motor, A accumulator, T tank. Stream numbers refer to Section 05.

05800 °C design point — states, flows and pressures

CO₂ heated to 700 °C at 300 bar; condensing at 10 °C. CO₂ flow 0.229 kg/s (1,820 lb/h). Two-stage expansion with an intermediate receiver at 116 bar. Enthalpy reference IIR.

#LocationPressure
bar / psia
Temperature
°C / °F
Enthalpy
kJ/kg / BTU/lb
Density
kg/m³ / lb/ft³
Phase
1Pump suction (receiver)45.0 / 6538 / 46220 / 95879 / 54.85subcooled liquid
2Pump discharge300.0 / 4,35136 / 97263 / 113925 / 57.74compressed liquid
3Recuperator cold out / heater in300.0 / 4,351339 / 642761 / 327260 / 16.22supercritical
4Heater out / HP admission294.0 / 4,264700 / 12921220 / 525150 / 9.34supercritical
4aHP exhaust / LP admission (V-202)116.2 / 1,685589 / 10911089 / 46870 / 4.37supercritical
5LP cylinder exhaust45.9 / 666492 / 918979 / 42132 / 1.98superheated vapour
6Recuperator hot out / condenser in45.9 / 66646 / 115481 / 20796 / 6.01superheated vapour
30 50 75 100 150 200 300 400 200 400 600 800 1000 1200 Specific enthalpy, kJ/kg (BTU/lb = × 0.430; IIR reference) Pressure, bar (log) — psia = bar × 14.5 100 °C 300 °C 500 °C 700 °C State 1: 220 kJ/kg, 45 bar1 State 2: 263 kJ/kg, 300 bar2 State 3: 761 kJ/kg, 300 bar3 State 4: 1220 kJ/kg, 294 bar4 State 4a: 1089 kJ/kg, 116 bar4a State 5: 979 kJ/kg, 46 bar5 State 6: 481 kJ/kg, 46 bar6 heater (flue 800 °C) recuperator 114 kW HP + LP cylinders
CO₂ pressure–enthalpy diagram, 800 °C case: 1→2 pump, 2→3 recuperator, 3→4 flue-gas heater, 4→4a HP cylinder, 4a→5 LP cylinder, 5→6 recuperator, 6→1 condenser.
Stream / dutyMetricImperial
Wood firing146.5 kW · ≈ 35 kg/h500,000 BTU/h · ≈ 77 lb/h
Flue gas 800 → 369 °C (HX-101)0.21 kg/s1,680 lb/h · 1,472 → 696 °F
Heat to CO₂ (HX-101)105.1 kW358,600 BTU/h
Air preheater (HX-104), flue 369 → 150 °C53.4 kW182,200 BTU/h
CO₂ mass flow0.229 kg/s · 824 kg/h1,820 lb/h
Liquid CO₂ to pump15.6 L/min4.1 gpm
CO₂ at HP admission (4)1.53 L/s3.2 ft³/min
CO₂ at LP exhaust (5)7.23 L/s15.3 ft³/min
Recuperator (HX-102)114.1 kW389,300 BTU/h
Condenser (HX-103)59.7 kW203,700 BTU/h
Glycol/creek water 5 → 8 °C≈ 17 m³/h≈ 75 gpm · 41 → 46 °F
Hydraulic oil at 207 bar147 L/min38.8 gpm at 3,000 psi
…or at 350 bar87 L/min23.0 gpm at 5,000 psi

Power balance

Wood firing
146.5 kW (500,000 BTU/h)
Heat to CO₂
105.1 kW (358,600 BTU/h)
Stack + casing loss
41.4 kW (141,300 BTU/h)
Condenser rejection
59.7 kW (203,700 BTU/h)
Expander work (HP + LP)
55.1 kW (73.9 hp)
Gross hydraulic
50.7 kW (68.0 hp)
CO₂ pump drive (HM-303)
11.5 kW (15.4 hp)
Net hydraulic
39.2 kW (52.6 hp)

Energy check: 105.1 kW heat + 9.8 kW pump = 55.1 kW expander + 59.7 kW condenser. Cycle efficiency 37.4 %; wood-to-net hydraulic 26.8 %. Fans and glycol pump (≈ 2–3 kW) come on top. They can be hydraulically driven from the output, or run from a small battery/solar bank.

06Expander and hydraulic coupling

At 700 °C / 300 bar the CO₂ expands across a 4.7 : 1 volume ratio. A single cylinder would need about 20 % cutoff, and the rod force would fall about 5 : 1 over the stroke, which is a poor match for a fixed-area hydraulic plunger. The design therefore uses compound expansion, as in a steam engine. A high-pressure cylinder expands 294 → 116 bar into the intermediate receiver V-202, and a low-pressure cylinder expands 116 → 46 bar. Each stage has a pressure ratio of about 2.5, and both pistons sit on one rod with the hydraulic plungers.

Over a stroke the combined force still varies about 2 : 1. A three-area stepped plunger (15 / 30 / 60 cm², switched by digital valves DV-301) keeps the CO₂ force matched to the 207 bar accumulator to within about ±15 %.

Free-piston tandem units (base design)

Item800 °C case500 °C case
Tandem units2, double-acting, 180° phased2
HP cylinder bore × strokeØ72 × 400 mm · 2.8 × 15.75 inØ82 × 400 mm
LP cylinder bore × strokeØ107 × 400 mm · 4.2 × 15.75 inØ111 × 400 mm
Intermediate pressure116 bar · 1,685 psia95 bar · 1,376 psia
Cycle rate / piston speed30 cpm · 0.40 m/s (79 ft/min)30 cpm
Peak rod force per unit136 kN · 30,600 lbf100 kN · 22,600 lbf
Mean rod force per unit69 kN · 15,500 lbf56 kN · 12,700 lbf
Plunger area, mean / max30.6 / 60.5 cm² · 4.7 / 9.4 in²25 / 45 cm²
Oil at 207 bar147 L/min · 38.8 gpm120 L/min · 31.8 gpm
Alternative: crank engine driving a hydraulic pump. A compound engine with a crank and flywheel at about 400 rpm (HP Ø56 mm, LP Ø83 mm, 100 mm stroke; peak gas loads 44 / 38 kN) can drive a variable-displacement axial-piston pump. The rotating mass smooths the force variation without digital hydraulics, and the parts are smaller. The cost is a crankcase, crossheads and a lubricated running gear kept away from the hot cylinders.

Hot-end engineering at 700 °C

  • Cylinders and heads: Inconel 718/625 liners and heads. Insulated outside, so heat leaks into the cylinder wall are not lost.
  • Rings: oil cannot be used. Options are carbon-graphite or silicon-nitride rings, or a labyrinth/clearance-seal piston. Expect blow-by of 2–5 %, which is in the efficiency assumption.
  • Valves: Nimonic/Stellite poppet valves (exhaust-valve practice from diesel engines), hydraulically actuated from the PLC.
  • Distance piece DP-201: a long, glycol-cooled rod section so the hydraulic chambers and seals stay below 60 °C (140 °F).
  • At 500 °C each of these becomes ordinary superheated-steam practice. This is the main reason for the recommended optimum.

07Site operation: wood, loads and control

  • Wood use: 146.5 kW of firing is about 35 kg/h (77 lb/h) of seasoned spruce or pine at 20 % moisture. That is ≈ 0.84 t (1,850 lb) per 24 h, roughly 0.8 cord per day. A log boiler with a 1–1.5 m³ firebox needs reloading every 3–5 h.
  • What 39–52 hp of hydraulic power runs: a small placer wash plant's trommel drive, feed and stacker conveyors and shaker deck (typically 20–50 hp combined). Large sluice water pumps (often 100–300 hp) are beyond it unless water is gravity-fed.
  • Batch firing: log boilers cycle through each burn. Hold the 800 °C flue temperature at HX-101 with primary/secondary air dampers and flue-gas recirculation. The hydraulic accumulator, plus a small thermal store, rides through refuelling dips.
The critical safety case: the fire cannot be switched off. If CO₂ flow stops (pump trip, valve fault), the HX-101 coil will overheat within minutes in 800 °C gas. Required protection: low-flow trip FSLL-201 that opens bypass PV-202 so CO₂ keeps circulating through the fail-safe air dump cooler HX-105; air dampers that close to starve the fire; coil skin thermocouples (TSHH-201); and a coil design that can survive a stagnant overheat to its relief-valve set pressure. Design to ASME BPVC Section I/VIII and B31.1 (or PED Category IV in the EU), with a CO₂ gas detector in any enclosure.

08Conclusions

Fire the CO₂ directly; design for about 500 °C and 200–250 bar; 800 °C flue is the 39 kW ceiling

  • Dropping the condenser to 5 °C (CO₂ condensing at 10 °C / 45 bar) adds about 30 % at the low-temperature end and is essential for the high-temperature cycle. In the Yukon summer it needs creek or groundwater cooling through a glycol loop.
  • The optimum heat source for a log boiler is a CO₂ heater coil in the flue gas, not a hot-water or thermal-oil loop.
  • From 500,000 BTU/h of wood: about 32 kW (43 hp) net at 500 °C / 200 bar, rising to 39.2 kW (52.6 hp) net and 50.7 kW (68 hp) gross at 700 °C / 300 bar with 800 °C flue gas. That is 147 L/min (38.8 gpm) of oil at 3,000 psi and 26.8 % wood-to-hydraulic efficiency.
  • At these temperatures, compound HP/LP cylinders with stepped hydraulic plungers (or a crank-driven pump) are required. The 500 °C design point keeps the hot end within proven steam-engine materials. That makes it the best choice for a remote site.

09Basis and assumptions

ParameterValue used
Wood firing500,000 BTU/h (146.5 kW) fuel input; 5 % casing/ash loss; flue gas 800 °C into the heater
Boiler modelFlue exits CO₂ heater at CO₂ inlet + 30 K; air preheater to 150 °C stack. Gives 71–78 % wood → CO₂
Cooling / condensing5 °C water/glycol; CO₂ condensing 10 °C (45.0 bar); subcooled to 8 °C
Heater approachDirect-fired: 100 K to 800 °C flue at the hot end. Water/oil loops: 5 K to loop supply
RecuperatorCounterflow, 10 K minimum pinch (checked along the full length)
Expander80 % isentropic (indicated) per stage; piston → hydraulic transfer 92 %
CO₂ feed pump65 % isentropic; driven by a hydraulic motor at 85 % (counted against the output)
Pressure losses2 % in the heater and 2 % in the low-side path
High-side pressureOptimised in 10 bar steps, capped at 200 or 300 bar
PropertiesCoolProp 8 (Span–Wagner CO₂); flue-gas cp 1.15 kJ/kg·K; wood 4.2 kWh/kg at 20 % moisture

Preliminary feasibility analysis, not a certified design. High-temperature CO₂ heater, cylinder and pressure-relief design require detailed engineering to the applicable codes and Yukon regulatory requirements.