Infinity Turbine develops advanced Organic Rankine Cycle (ORC) and Supercritical CO₂ Power Block systems for Data Center Prime Power and also convert data center, solar, geothermal, and industrial waste heat into clean electricity—maximizing energy efficiency and sustainability. Runs silent. No water usage. Power source includes Natural Gas and hydrogen.



Publication Title | LM2500 Gas Turbine

Gas Turbine Data Center Publications Search

Search GE Vernonva Gas Turbine Power for Data Center Publications search was updated real-time via Filemaker on:

Search GE Vernonva Gas Turbine Power for Data Center Publications | Return to Search List

Search Completed | Title | LM2500 Gas Turbine
Original File Name Searched: MSC01A_1211_B5_LM2500-Gas-Turbine_-r5b_rg.pdf | Google It | Yahoo | Bing


Previous Page | Next Page
lm2500-gas-turbine-110</TD> <TD valign=

Page | 110

LM2500 Combustion Turbine Course MILITARY SEALIFT COMMAND
7. Water Injection
a. b. c. Water is used for NOx emissions reduction.
The water is supplied from a ring header located around the compressor rear frame
assembly.
Hard formed stainless-steel distribution tubing connects the ring header to each fuel nozzle.
Classroom Discussion Point:
Water injection is used to reduce the temperature of combustion. High combustion temperature
produces an elevated NOx emission.
The water injection pump provides water at a pressure around 400 psig; around 15 gpm are
consumed at full load.