Page | 079 Taurus 70 Generator Set FIELD PERFORMANCE VERIFICATION TESTING The objective of site testing is typically to determine that the equipment furnished meets, at a minimum, the guaranteed performance claimed by the manufacturer. At Solar Turbines, we take this very seriously. In Section 1.0: Factory Testing of this proposal document, our comprehensive test procedures were described, including: Test Facilties Gas Turbine Acceptance Test Generator Testing Generator Set Acceptance Testing With the availablility of dynamic Generator Set Acceptance Testing of the generator set package, in an instrumented and calibrated test cell, and a corresponding test report; this might well be considered an alternative to site testing. However, where endurance testing of the installed equipment is desired, or site performance verification testing is otherwise required, Solar offers a service product to meet your specific needs. Field Performance Verification Test Procedure The declared Solar gas turbine generator set performance, and reference conditions associated with such performance are specified in Section 3.0: Performance and Emissions, of this proposal. These performance values are demonstrated during factory testing, and in instances where Solar has guaranteed performance, compliance with such guaranteed performance is evaluated based on the factory test results. Customers frequently request that performance values demonstrated during the factory tests be verified through field testing at site, and this document defines the test objectives and procedures for such field testing, to verify the Output Power and Heat Rate performance of the Solar gas turbine generator set(s). Solar Turbines has participated in the start up and site performance verification on thousands of gas turbine generator sets. This procedure has proven to be an effective way to verify proper package performance (Output Power and Heat Rate) for both the customer and Solar. Test Description Test Conditions. Engine performance testing at Solar’s factory allows the engine to be operated in steady, closely controlled conditions with redundant, calibrated instrumentation. Factory testing performed by Solar typically allows the most accurate evaluation of engine performance. The field tests described herein are intended to provide a site verification of the declared performance values for Output Power and Heat Rate, based on data obtained from the permanently installed package instrumentation, and other sources, such as Customer instrumentation. Other factors affect the field verification test results, such as power transformer (PT) and control transformer (CT) accuracy, the accuracy of the fuel analysis, etc.; many of which are beyond Solar’s scope of control. This results in a field test with an inherently lower accuracy than the factory test, and an allowance for this uncertainty must therefore be considered when evaluating the field test results as further explained herein. May 3, 2011 83 |